CB004 (General spec) / CB004-C4, -C6 (OIML Standard) logo menu-toggler menu-toggler

Have a question about this product?

ask-experts Ask Our Experts
Single Point Measurement for Commercial Scales

CB004 (General spec) / CB004-C4, -C6 (OIML Standard)

CB004
Features
  • Middle capacity
Specifications
Rated capacity
98.07 N{10 kgf}~980.7 N{100 kgf}
Safe overload
150% R.C.
Ultimate overload
200% R.C.
Rated output
2 mV/V±0.2 mV/V
Non-linearity
0.015% R.O.
Hysteresis
0.015% R.O.
Repeatability
0.02% R.O.
Creep
0.02% R.O./20 min
Creep recovery
0.02% R.O./20 min
Excitation, recommendation
12 V or less
Excitation, maximum
20 V
Zero balance
±0.1 mV/V
Input resistance
375 Ω ~ 425 Ω
Output resistance
345 Ω ~ 355 Ω
Insulation resistance
2,000 MΩ or more (DC50 V)(between bridge and main body)
Temp. range, compensated
-10 ℃ ~ 50 ℃
Temp. range, safe
-10 ℃ ~ 50 ℃
Temp. effect on zero
0.04% R.O./10 ℃
Temp. effect on output
0.012% LOAD/10 ℃
Cable
φ3.2, 4-cores shielded 40 cm cable directly attached, and cable end is separated.
Class of protection
IP64 or equivalent
Material of element
Aluminum alloy
Durability
1,000,000 times with rated load applied.
List of Part Numbers
Part Number
Rated Capacity
Natural Frequency
Rated Displacement
Weight (Approx.)
CB004-10K
10 kg
160 Hz
0.55 mm
350 g
CB004-15K
15 kg
200 Hz
0.55 mm
350 g
CB004-20K
20 kg
230 Hz
0.55 mm
350 g
CB004-25K
25 kg
250 Hz
0.55 mm
350 g
CB004-30K
30 kg
270 Hz
0.55 mm
360 g
CB004-35K
35 kg
300 Hz
0.55 mm
360 g
CB004-45K
45 kg
330 Hz
0.55 mm
370 g
CB004-60K
60 kg
380 Hz
0.55 mm
380 g
CB004-100K
100 kg
480 Hz
0.55 mm
390 g