Compression Measurement for Industrial Weighing Systems
CCS1 Series
Features
- High capacity general purpose load cell
| CAD Files | CCS1-50T (30KB) |
| CAD Files | CCS1-100T (36KB) |
| CAD Files | CCS1-200T (35KB) |
| CAD Files | CCS1-300T (35KB) |
| Specification Sheet | No.KT52282-2 (77KB) |
| Instruction manual (PDF) | No.KT60253-1 (75KB) |
Rated capacity |
490.3 kN {50 tf}~2.942 MN {300 tf} |
Safe overload |
150% R.C. |
Ultimate overload |
200% R.C. |
Rated output |
2 mV/V±0.02 mV/V |
Non-linearity |
0.3% R.O. |
Hysteresis |
0.3% R.O. |
Repeatability |
0.15% R.O. |
Excitation, recommended |
12 V or less |
Excitation, maximum |
20 V |
Zero balance |
±0.02 mV/V |
Input resistance |
350 Ω±3.5 Ω |
Output resistance |
350 Ω±5 Ω |
Insulation resistance |
2,000 MΩ or more (DC50 V) (between bridge and main body) |
Temp. range, compensated |
-10℃ ~ 70℃ |
Temp. range, safe |
-20℃ ~ 100℃ |
Temp. effect on zero |
0.05% R.O./10℃ |
Temp. effect on output |
0.1% LOAD/10℃ |
Cable |
φ10, 4 -cores shielded 3 m cable directly attached, Y-crimp type terminal lugs are attached at cable end. |
Class of protection |
IP64 or equivalent |
Material of element |
Alloy steel |
Paint |
Painted by epoxy resin (Munsell 6GY3.5/2 half-polished resemblance color) |
Durability |
1,000,000 times with rated load applied. |
Parts No. |
Rated capacity |
Natural frequency |
Rated displacement |
Weight (Approx.) |
|---|---|---|---|---|
CCS1-50T |
490.3 kN {50 tf} |
9,700 Hz |
0.16 mm |
10 kg |
CCS1-100T |
980.7 kN {100 tf} |
8,200 Hz |
0.19 mm |
18 kg |
CCS1-200T |
1.961 MN {200 tf} |
6,900 Hz |
0.23 mm |
34 kg |
CCS1-300T |
4.903 MN {500 tf} |
4,800 Hz |
0.34 mm |
50 kg |
Expansion plate, Bearing plate, Mounting plate |