FSU Series logo menu-toggler menu-toggler

Have a question about this product?

Ask Our Experts

FSU Series

Features
  • Aluminum single point load cell
  • Full bridge type
Resources
CAD Files FSU-0.5~15K (32KB)
Specification Sheet No.KT52811-2-B (103KB)
Instruction manual (PDF) No.KT60248-1 (41KB)
Specifications
Rated capacity
4.903 N{0.5 kgf}~147.1 N{15 kgf}
Safe overload
450% R.C.
Ultimate overload
600% R.C.
Rated output
0.5 mV/V±0.05 mV/V (FSU-0.5K : 0.5 mV/V±0.075 mV/V)
Non-linearity
0.1% R.O.
Hysteresis
0.1% R.O.
Repeatability
0.1% R.O.
Creep
0.15% R.O./20 min
Creep recovery
0.15% R.O./20 min
Excitation, recommended
5 V or less
Excitation, maximum
8 V
Zero balance
±0.4 mV/V
Input resistance
340 Ω±50 Ω
Output resistance
340 Ω±50 Ω
Insulation resistance
1,000 MΩ or more (DC50 V) (between bridge and main body)
Temp. range, compensated
0℃ ~ 60℃
Temp. range, safe
-10℃ ~ 80℃
Temp. effect on zero
±1% R.O./10℃
Temp. effect on output
±1% LOAD/10℃
Lead wire
AWG30, 150 mm directly attached, cable end is separated
Class of protection
IP00 or equivalent
Material of element
Alluminium alloy
Weight
Approx. 30 g
Durability
1,000,000 times with rated load applied.
Effect of eccentric load
– The center of loading plate and also the center of load cell should be the same position.
– Error is within 0.8% R.O. applied with 1/2 of rated capacity at the position of 50 mm of eccentricity.
List of Part Numbers
Parts No.
Rated capacity
FSU-0.5K
4.903 N {0.5 kgf}
FSU-1K
9.807 N {1 kgf}
FSU-2K
19.61 N {2 kgf}
FSU-5K
49.03 N {5 kgf}
FSU-15K
147.1 N {15 kgf}