UL/ULA Series logo menu-toggler menu-toggler

Have a question about this product?

Ask Our Experts
Specialty Applications

UL/ULA Series

Features
  • Low capacity, universal, bending beam load cell
  • Excellent when small force measurements are required
Resources
CAD Files UL-2GR (50KB)
CAD Files ULA-10GR ~ 100GR (46KB)
Specification Sheet UL-2GR: No.KT51998-2 (137KB)
Specification Sheet ULA-10GR~100GR: No.KT52743-2 (146KB)
Instruction manual (PDF) No.KT60243-1-H (59KB)
Specifications
Rated capacity
19.61 mN{2 gf}~980.7 mN{100 gf}
Safe overload
130% R.C.
Ultimate overload
130% R.C.
Rated output
±1.75 mV/V±0.35 mV/V (UL-2GR: ±0.65 mV/V±0.15 mV/V)
Non-linearity
0.2% R.O. (UL-2GR: 0.3% R.O.)
Hysteresis
0.2% R.O. (UL-2GR: 0.3% R.O.)
Repeatability
0.2% R.O. (UL-2GR: 0.3% R.O.)
Excitation, recommended
3 Vor less
Excitation, maximum
6 V
Zero balance
±0.175 mV/V (UL-2GR: ±0.05 mV/V)
Input resistance
270 Ω±40 Ω
Output resistance
270 Ω±40 Ω
Insulation resistance
1,000 MΩ or more (DC50 V)
Temp. range, compensated
0℃ ~ 50℃
Temp. range, safe
-10℃ ~ 60℃
Temp. effect on zero
0.5% R.O./10℃
Temp. effect on output
0.5% LOAD/10℃
Cable
4-cores parallel vinyl 60 cm directly attached, cable end is separated
Class of protection
IP30 or equivalent
Durability
1,000,000 times with rated load applied.
List of Part Numbers
Parts No.
Rated capacity
Natural frequency
Rated displacement
Weight
(Approx.)
UL-2GR
19.61 mN {2 gf}
60 Hz
±0.12 mm
100 g
ULA-10GR
98.07 mN {10 gf}
133 Hz
±0.4 mm
100 g
ULA-20GR
196.1 mN {20 gf}
192 Hz
±0.4 mm
100 g
ULA-50GR
490.3 mN {50 gf}
208 Hz
±0.4 mm
100 g
ULA-100GR
980.7 mN {100 gf}
286 Hz
±0.4 mm
100 g